 Chokes and inductors
For high frequency and EMC RF chokes, LBC series, axial
Series/Type: B82144A November 2005
7ffARspp
Date:
(c) EPCOS AG 2005. Reproduction, publication and dissemination of this publication and the information contained therein without EPCOS' prior express consent is prohibited.
RF chokes LBC series
LBC choke (Large Bobbin Core) Rated current 20 to 2200 mA Rated inductance 1 to 100 000 NH Construction
Large ferrite drum core Winding: enamel copper wire Flame-retardant lacquer coating
B82144A
Features
Very wide inductance range High rated current RoHS-compatible (see page 6)
Applications
RF blocking and filtering Decoupling and interference suppression For telecommunications (12- or 16-kHz blocking filter), automotive
electronics, energy-saving lamps, entertainment electronics Terminals
Central axial leads, lead-free tinned
Marking Inductance indicated by color bands to IEC 60062 Delivery mode Taped, Ammo and reel packing (packing see page 8) Dimensional drawing
651 53
o0.8 max.
o5.2 max.
12 max. (IEC 60294)
60.5
3.5 min.
14.8 max. lacquered/lackiert
IND0431-4
Minimum lead spacing 15 mm Approx. weight 1.1 g
Please read the Important notes at the end of this document.
100.25 100.25
2
11/05
RF chokes LBC series
Characteristics and ordering codes For further technical data see page 6. LR H Tolerance1) 1.0 10 % 1.5 ^ K 2.2 3.3 4.7 6.8 10 15 22 33 47 68 100 150 220 330 470 680 1000 1500 2200 3300 4700 6800 10000 15000 22000 5% ^J Qmin 40 40 40 40 40 40 60 60 50 40 40 30 50 50 50 50 40 30 60 60 60 60 60 60 50 50 50 fQ MHz 7.96 7.96 7.96 7.96 7.96 7.96 2.52 2.52 2.52 2.52 2.52 2.52 0.796 0.796 0.796 0.796 0.796 0.796 0.252 0.252 0.252 0.252 0.252 0.252 0.0796 0.0796 0.0796 IR mA 2200 2100 1900 1750 1600 1500 1400 1250 1100 900 800 700 600 500 400 330 280 240 200 160 120 110 90 80 60 50 40 Rmax 0.08 0.09 0.11 0.13 0.16 0.19 0.22 0.28 0.35 0.43 0.50 0.60 0.70 0.90 1.60 1.90 2.50 2.80 3.80 6.00 9.00 12.0 20.0 30.0 42.0 68.0 120 fres, min MHz 200 190 140 120 100 80 60 20 12 8.0 5.0 4.5 3.5 3.0 2.4 2.0 1.5 1.3 1.2 1.0 0.8 0.6 0.5 0.4 0.35 0.30 0.26
B82144A
Ordering code (reel packing) 2) B82144A2102K000 B82144A2152K000 B82144A2222K000 B82144A2332K000 B82144A2472K000 B82144A2682K000 B82144A2103K000 B82144A2153K000 B82144A2223K000 B82144A2333J000 B82144A2473J000 B82144A2683J000 B82144A2104J000 B82144A2154J000 B82144A2224J000 B82144A2334J000 B82144A2474J000 B82144A2684J000 B82144A2105J000 B82144A2155J000 B82144A2225J000 B82144A2335J000 B82144A2475J000 B82144A2685J000 B82144A2106J000 B82144A2156J000 B82144A2226J000
1) Closer tolerances upon request. 2) For Ammo pack the last digit has to be a 9. Example: B82144A2102K009
Please read the Important notes at the end of this document.
3
11/05
RF chokes LBC series
Characteristics and ordering codes (continued) For further technical data see page 6.. LR H 33000 47000 68000 100000 3% ^A Tolerance1) 5% ^J Qmin 50 40 40 40 fQ MHz 0.0796 0.0796 0.0796 0.0796 IR mA 35 30 25 20 Rmax 150 230 290 420 fres, min MHz 0.22 0.18 0.15 0.12
B82144A
Ordering code (reel packing) 2) B82144A2336J000 B82144A2476J000 B82144A2686J000 B82144A2107J000
For telecommunications in the blocking filter for 12-kHz and 16-kHz counting pulses 980 1450 2600 3050 5330 25 25 20 25 20 0.016 0.016 0.012 0.016 0.012 200 140 120 100 90 3.8 6.0 11.0 12.0 25.0 1.2 1.0 0.7 0.6 0.5 B82144A2984A000 B82144A2145A500 B82144A2265A000 B82144A2305A500 B82144A2535A300
1) Closer tolerances upon request. 2) For Ammo pack the last digit has to be a 9. Example: B82144A2336J009
Please read the Important notes at the end of this document.
4
11/05
RF chokes LBC series
Impedance |Z | versus frequency f measured with impedance analyzer HP 4191A / HP 4194A
10 7 | Z | 10 6 10 5 10 4 10 3
10 1
IND0131-7
B82144A
Inductance L versus DC load current IDC measured with LCR meter HP 4275A
10 5 H L 10 4
IND0132-9
100000 H 10000 H 1000 H 100 H
B82144A
100000 H 10000 H
B82144A
10 H 1 H
10 3
1000 H
10 2
100 H
10 H
10
2
10 1 10 0 5 10
10 0
_1
1 H
10 6
10 7
10 8 f
Hz 10 9
10
10
_2
10
_1
10 0
A 10 1 I DC
Q factor versus frequency f measured with impedance analyzer HP 4194A
200 B82144A Q 100000 H 10000 H 1000 H 100 H 10 H 1 H
IND0133-R
Current derating Iop/IR versus ambient temperature TA (rated temperature TR = 40 C)
1.2
IND0552-S-E
I op IR
1.0
0.8
100
0.6
0.4
0.2
0
0
10 4 10 5 10 6 10 7 f Hz 10 8
0
20
40
60
80
100
C 140
TA
5 11/05
Please read the Important notes at the end of this document.
RF chokes LBC series
General technical data Rated inductance LR
B82144A
Measuring frequency: L 10 H = 1 MHz 10 H < L 4700 H = 100 kHz L > 4700 H = 10 kHz Measuring current: 1 mA Distance between measuring clamps: 25.4 mm Measured with HP 4342A Maximum permissible DC current referred to 40 C ambient temperature, for derating see below 10% (referred to initial value) at IR at 20 C ambient temperature Measured at 20 C ambient temperature, distance between measuring clamps: 25.4 mm Measured with Scalar Network Analyzer ZAS from Rohde & Schwarz 55/125/56 (-55 C/+125 C/56 days damp heat test) to IEC 60068-1 235 C, 2 s, 90% wetting to IEC 60068-2-20, test Ta To IEC 60068-2-20, test Tb 260 C, 10 s To IEC 60068-2-21, test Ua 20 N RoHS-compatible is defined as compatible with the following documents: DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 13 February 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment COM (2004) 606 final Proposal for a COUNCIL DECISION amending Directive 2002/95/EC of the European Parliament and of the Council for the purposes of establishing the maximum concentration values for certain hazardous substances in electrical and electronic equipment. When bending the leads, take care that the start-of-winding areas at the face ends (protected by glue and lacquer) are not subjected to any mechanical stress.
Q factor Qmin Rated current IR
Inductance decrease L/L0 DC resistance Rmax Resonance frequency fres, min Climatic category Solderability Resistance to soldering heat Tensile strength of leads RoHS-compatible
Mounting information
Please read the Important notes at the end of this document.
6
11/05
RF chokes LBC series
Color coding of the inductance value
B82144A
The inductance value and tolerance are encoded by means of colored bands in accordance with IEC 60062. The basic unit is H. 1st band 2nd band 3rd band 4th band 1st digit of inductance value 2nd digit of inductance value multiplier, i.e. the power of ten, by which the first two digits have to be multiplied. tolerance of the inductance value.
Color code Colorless Silver Gold Black Brown Red Orange Yellow Green Blue Violet Grey White Examples:
1st band = 1st digit -- -- -- -- 1 2 3 4 5 6 7 8 9
2nd band = 2nd digit -- -- -- 0 1 2 3 4 5 6 7 8 9
3rd band = multiplier -- x 10-2 H = x 10-1 H = x 100 H = x 101 H = x 102 H = x 103 H = 0.01 H 0.1 H 1,01 H 10,01 H 100,01 H 1000,01 H
4th band = tolerance 20 % (M) 10 % (K) 5 % (J) -- 2 % (G)
x 104 H = 10000,01 H x 105 H = 100000,01 H
Special designs manufactured to customer specifications are identified by a white tolerance band.
1st band Yellow 4 Brown 1
2nd band Violet 7 Green 5
3rd band
4th band
Decoding = 47 x 0.1 H 10 % = 4.7 H 10 %
Gold Silver x 0.1 H 10 % Red Gold x 100,0 H 5 %
= 15 x 100,0 H 5 % = 1500,0 H 5 %
Please read the Important notes at the end of this document.
7
11/05
RF chokes LBC series
Packing Reel packing
B82144A
o30.50.15
30
o360 _ 1
30
o82+1 o90
30
Axial
n w Label Etikett
IND0452-V
n (mm) w (mm)
72 +1 84 max.
Ammo packing
H
Axial L (mm) B (mm)
L
265 max. 75 max. 125 max.
H (mm
SSB1858-W
B
Packing units Reel packing pcs./reel Axial 1500 Ammo pack pcs./pack. 1250
Please read the Important notes at the end of this document.
8
11/05
Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as "hazardous"). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, CeraDiode, CSSP, PhaseCap, PhaseMod, SilverCap, SIFI, SIMID, SIKOREL, SIOV, SIP5D, SIP5K, TOPcap, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
9
11/05


▲Up To Search▲   

 
Price & Availability of B82144A2103K000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X